<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>دانشگاه علوم پزشکی شهید بهشتی</PublisherName>
				<JournalTitle>دوماهنامه علمی - پژوهشی طب توانبخشی</JournalTitle>
				<Issn>2251-8401</Issn>
				<Volume>4</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2015</Year>
					<Month>06</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Developing and evaluating the reliability of acceptable noise level test in Persian language</ArticleTitle>
<VernacularTitle>ساخت و بررسی پایایی آزمون تراز قابل قبول نویز در زبان فارسی</VernacularTitle>
			<FirstPage>109</FirstPage>
			<LastPage>117</LastPage>
			<ELocationID EIdType="pii">1100032</ELocationID>
			
<ELocationID EIdType="doi">10.22037/jrm.2015.1100032</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>امیر</FirstName>
					<LastName>احمدی</LastName>
<Affiliation>1.	دانشجوی کارشناسی ارشد، گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی تهران. تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>جمیله</FirstName>
					<LastName>فتاحی</LastName>
<Affiliation>2.	مربی گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی تهران. تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-9145-3587</Identifier>

</Author>
<Author>
					<FirstName>احمد</FirstName>
					<LastName>کشانی</LastName>
<Affiliation>2.	مربی گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی تهران. تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>حمید</FirstName>
					<LastName>جلیلوند</LastName>
<Affiliation>3.	دکترای تخصصی شنوایی شناسی، گروه شنوایی شناسی، دانشکده علوم توانبخشی، دانشگاه علوم پزشکی شهید بهشتی. تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-2351-5918</Identifier>

</Author>
<Author>
					<FirstName>یحیی</FirstName>
					<LastName>مدرسی</LastName>
<Affiliation>4.	زبانشناس، استاد دانشگاه تهران، پژوهشگاه علوم انسانی و مطالعات فرهنگی، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>شهره</FirstName>
					<LastName>جلایی</LastName>
<Affiliation>5.	استادیار آمار زیستی، دانشکده علوم توانبخشی دانشگاه علوم پزشکی تهران . تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-2547-0303</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2015</Year>
					<Month>01</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>Background and Aim: Problem with tolerating Levels of amplified background noise is one of the most complications of people with hearing loss. Acceptable noise level (ANL) test can be used as an accurate and valid test to evaluate the ability of tolerating levels of noise among peoples. The aims of this study were to develop and evaluate the reliability of acceptable noise level test in Persian language. &lt;br /&gt;Materials and Methods: After selecting suitable materials for multi talker babble noise and running speech signals, Material were recorded in controlled situation in professional recording studio. The test was conducted twice with one week separation on 66 normal people with mean age of 25±4. &lt;br /&gt;Results:  Statistical analysis showed the mean Acceptable Noise Level in two repeats had no significant difference (0.05 &gt;P). The correlation coefficient between the first and second repeats of (ANL) was r=0/847 (0.001&gt; P) and Inter Class Correlation coefficient between the first and second repeats was 0/920 (0.001&gt; P). &lt;br /&gt;Conclusion: Based on the findings, the Persian version of acceptable noise level test had desired reliability in the individual with normal hearing. Implementation simplicity, non-invasive and the low cost are the benefitsfor the clinical use of this test.</Abstract>
			<OtherAbstract Language="FA">مقدمه و اهداف &lt;br /&gt;یکی از اصلی ترین علل عدم پذیرش سمعک توسط افراد کم شنوا مشکل با نویز محیطی تقویت شده می باشد. آزمون تراز قابل قبول نویز می تواند به عنوان معیار معتبری برای سنجش توانایی افراد در تحمل نویز محیطی مورد استفاده قرار گیرد. این مطالعه با هدف ساخت و بررسی پایایی آزمون تراز قابل قبول نویز در زبان فارسی بر روی افراد با شنوایی هنجار طراحی و اجرا گردیده است. &lt;br /&gt;مواد و روش ها &lt;br /&gt;این مطالعه از نوع ساخت آزمون به شمار می آید که طی آن مواد آزمونی لازم برای اجرای آزمون تراز قابل قبول نویز در زبان فارسی ساخته و استاندارد می شود. پس از انتخاب مواد مناسب برای نویز همهمه گفتاری و گفتار پیوسته، هر دوی این سیگنال ها در استودیوی ضبط صدا با شرایط کنترل شده ضبط گردید. آزمون در دو نوبت با فاصله یک هفته بر روی 66 فرد با شنوایی هنجار با میانگین سنی 4± 25 انجام شد و پایایی نتایج آزمون در دو تکرار مورد بررسی قرار گرفت. &lt;br /&gt;یافته ها &lt;br /&gt;میانگین امتیازات آزمون تراز قابل قبول نویز در دو تکرار مورد مقایسه قرار گرفت  و نتایج حاکی از عدم وجود تفاوت معنی داری  بود(05/0&lt;P)، همچنین ضریب همبستگی بین تکرار اول و دوم آزمون برابر 847/r= (001/0&gt;P) و ضریب همبستگی درون گروهی بین تکرار اول و دوم  آن برابر 920/0 (001/0&gt;P) بود، که مقادیر فوق حاکی از همبستگی بالا و معنی دار و همچنین پایایی معنی دار دو تکرار بوده است. &lt;br /&gt;نتیجه گیری &lt;br /&gt;بر اساس یافته های مطالعه حاضر، نسخه فارسی آزمون تراز نویز قابل قبول از پایایی مطلوبی در افراد دارای شنوایی هنجار برخوردار است. سادگی اجرا، غیر تهاجمی بودن و هزینه پایین، کاربرد بالینی این آزمون را بالا می برد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">تراز قابل قبول نویز</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">نویز زمینه قابل تحمل</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ارزیابی پایایی</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://medrehab.sbmu.ac.ir/article_1100032_0d1d5a47adf070e0ddcaf1a012aa3084.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
